        OPTIC-4 Accessoires
Micro-vial and liner block

This block can hold up to 10 liners and micro vials for DMI sample preparation.

Part Number:   2406-2290   Microvial and liner block


CO2 Cooling Kit

This cooling kit gives to possibility to cool the injector faster and also below room temperature. This kit requires a CO2 bottle with dip pipe, the liquid CO2 is used to cool down the injector body down to about -70°C.

Part Number:   H500009   Injector Liquid CO2 cooling option for OPTIC-4
Backflush

With automated liner exchange, it is necessary to open the injector head before the liner is transferred from, or to the injector. When the injector- head is open, air and water can flow into the system. This can be harmful to the GC-column and MS. Therefore a back flush of the injector is necessary. To avoid practical problems, ATAS GL developed a new tool, the T-joint, an practical solution for the use of back flush in GC.

The only difference between normal installation and using the T-joint for back flush is that the column goes through the T-joint to the injector. The original flow path is exactly the same as normal without back-flush. After installation the back-flush is then introduced from the bottom of the injector.
Mounting tool for installation GC-column to the OPTIC-4 injector

Column always at perfect depth!!


 
  • Put nut, ferrule and tool onto the column
  • Connect nut and tool
  • Cut the column
  • Disconnect tool
  • Put column into the injector







  • Part Number:   H500024   OPTIC-4 Column Fitting Jig
    Standard supplied with OPTIC-4




    Merlin MicroSeal

    HIGH PERFORMANCE ALTERNATIVE FOR TRADITIONAL DISC SEPTA

    The Merlin Microseal is a long-life replacement for the standard septum used in Gas Chromatography. High pressure capability and resistance to wear make it the most unique septum on the market today. The Microseal fits standard in the OPTIC-4 inlet without modification. Features and Benefits

     
  • Eliminate septa coring and crumbling.
  • O-ring detail seals needle for precise injections.
  • Reliability and performance during extended runs.
  • Low insertion force for easy manual injections.
  • Duckbill seals more tightly at higher pressures.

  • Part Number:   A100111   High-Pressure Merlin Microseal

    How the Merlin Microseal Works













      OPTIC-4